System Fault/Error Alerts
A list of milking unit fault codes are displayed to indicate the type of failure. These alerts may be displayed during or after milking:
The fault indication format is E 01 (# = error number) alternating with Out# (# = number of outputs).
-
Error Alert
Error |
Type |
Description |
Response |
---|---|---|---|
E 02 |
Milk dump delay |
Resistance to milk discharge / the milk is not discharged quickly enough - Alert appears after cluster removal to indicate a possible milk measuring inaccuracy. |
Afimilk MPC dumps the portions of milk into the milk line. The MPC body design allows fast discharge of the milk when the valve is opened. Delays in milk discharge may cause measurement inaccuracies alongside delays in removal. Check the following:
|
E 02F |
Milk dump delay |
Dramatic discharge problem - the milk meter does not empty, milk overflows through the measuring chamber. Alert appears as soon as the error is detected. Problem usually occurs from a valve or severe mechanical malfunction. In such situations, the Afimilk MPC stops measuring; pulsation continues to function. |
|
E 03 |
Communication fault |
Indicates a momentary failure in communication. |
Press one of the keys on the control box. If the problem persists, OR if the alert appears again, replace the Afimilk MPC Control Box. |
E 04 |
Software failure |
Occurs when software fails. Can be caused by:
|
To resolve the issue:
Note: Replace the device if these possibilities fail to resolve the issue. |
-
Outputs Alert
Indicates a device may be short-circuiting (over-current at an output). Apparatus controlled by the Afimilk MPC and its corresponding fault alerts are listed below.
If an output alert appears, press one of the keys of the control box. If the problem persists OR if the alert appears again, the device needs to be replaced or fixed.
Output Message |
Device Correlated |
---|---|
Out1 |
Removal Piston Solenoid |
Out2 |
Valve Solenoid |
Out3 |
Vacuum Valve Solenoid |
Out4 |
Pulsator Front |
Out5 |
Pulsator Rear |