Maintain Solenoid and Clean-air Line
Proper maintenance is essential for milk meter functionality and longevity. Vacuum and clean air lines must be kept dry, and drained regularly.
Drain valve
A properly functioning drain valve drains water that has condensed in the line.
-
Check the valve condition once a week.
-
Ensure the valve is totally sealed when there is a vacuum, and that it is open when the parlor is not in operation.
Suction filter
-
Remove the filter from the line once a month.
-
Clean the filter with compressed air.
-
Change the filter when damaged or partially dirty.
Clean-air line
Warning: DO NOT WASH the clean-air line!
-
Check the clean-air line frequently for water - open the ball valve once a week, to drain any water.